The Doppelgänger Core reader's own CARDS page in a desktop browser and on a phone, decoding a 37 bit H10304 read of FC 1201 CN 80441

Doppelgänger RFID Development Board

$60.00

PPE Doppelgänger RFID Development Board Universal Wiegand & Clock/Data Integration Platform The PPE Doppelgänger RFID Development Board is the board inside every PPE long range interpreter, sold by itself for putting...

SKU: LONGRANGE-DEVBRD-001
Availability : In Stock Pre order Out of stock
Description

PPE Doppelgänger RFID Development Board

Universal Wiegand & Clock/Data Integration Platform

The PPE Doppelgänger RFID Development Board is the board inside every PPE long range interpreter, sold by itself for putting behind a reader you already own. Built for professional red teamers and physical penetration testers, it takes 12 V in, passes the same 12 V out to the reader, brings the reader's two 5 V data lines in through a divider that makes them safe for the processor, and decodes, stores and serves every card. It speaks both Wiegand and Clock/Data (including Paxton Net2). Designed for reduced wiring and simplified installation, making it an ideal choice for custom long-range data interpreter builds.

The reader captures and stores every card on its own, connected or not. No phone, network or app has to be connected for that. Bluetooth is only how the ATLAS app connects to the reader, and a browser reaches the reader over its WiFi.

A Reader You Supply Is Not a PPE Interpreter

A reader bought on its own, from a reseller, on eBay or second hand, is not equivalent to the PPE interpreter of the same name. It can be dead on arrival. It can be an older revision that does not read every technology. Readers sold under the same model name can differ by their full part number, and the part number decides which card technologies a reader reads at all. The PPE interpreters are factory readers of a specific model and configuration, and all three assembled interpreters, the R90SE, the MaxiProx 5375 and the Paxton P200, ship with the beep disabled. Check the exact part number of a reader before you build on it, and expect it to read less than the interpreter of the same name.

Key Features:

Dual Protocol Support

Supports both 5V Wiegand data signals and Clock/Data protocols (including Paxton Net2). The board does not read cards. The reader does, and the board reads the reader, so what you capture is whatever that exact reader reads. Readers PPE documents with this board:

Reader, exact part What that part reads Reader output
HID MaxiProx 5375 125 kHz: every HID card and tag in formats up to 85 bits. ProxCard II, ISOProx II, DuoProx II, Smart ISOProx II, Smart DuoProx II, ProxCard Plus, ProxKey II, MicroProx Tag, the ProxPass active vehicle tag, and the 125 kHz side of the HID Proximity & MIFARE Card Wiegand
HID iCLASS SE R90 13.56 MHz only: HID iCLASS Seos, iCLASS SE, iCLASS SR and standard iCLASS, MIFARE Classic and MIFARE DESFire EV1 cards that carry an SIO, and the serial number of a MIFARE card that does not Wiegand
HID Indala ASR-620++ 125 kHz Indala Wiegand
Paxton Net2 proximity readers Paxton Net2 tokens, fobs and cards Clock and data, 75 bit
Paxton KP75 keypads Paxton Net2 credentials and key presses Clock and data, 75 bit, and 55 or 56 bit for a key

What each reader reads above is true of the exact readers PPE builds with. The MaxiProx and the R90SE are also sold assembled, as the PPE long range interpreters.

Doppelgänger Core Firmware

Ships ready to run Doppelgänger Core firmware, designed specifically for the Doppelgänger Development Board. Firmware is installed and updated two ways: from the Doppelgänger ATLAS app, or in Chrome or Edge at https://atlas.mwgroup.io/flash. That page always carries the current release. An update keeps the reader's settings and captured cards. For an update over the cable, run the board from USB alone and leave the 12 V supply disconnected.

Every Format the Board Decodes

Wiegand

Behind a Wiegand reader the board names the format of a read from the length of the frame. This is the complete list. Which of these a build produces depends on the reader, because a reader only sends the formats of the cards it can read.

Bits Format Logged as Decode and ATLAS can show it as
4 One key pressed on an HID keypad PIN
26 HID H10301 H10301 AWID26, ind26
27 Indala 27 ind27 indasc27, Tecom27
28 2804 Wiegand 2804W
29 Indala 29 ind29
30 ATS Wiegand ATSW30
31 HID ADT ADT31
32 Wiegand 32 WIE32 HCP32, HPP32, Kastle, Kantech, EM410x
32 PIV, MIFARE or FASC-N card serial. Stored as the card's serial PIV/MiFare/FASC-N
33 HID D10202 D10202
34 HID H10306 H10306 N10002, Optus34, SMP34, BQT34
35 HID Corporate 1000 C1k35s (C-1000)
36 HID Simplex (S12906) S12906 C15001, Sie36
37 HID H10304 H10304 H10302, H10320, P10004, HGen37, MDI37
38 BQT 38 BQT38 ISCS
39 Pyramid 39 PW39
40 P10001, Verkada 40, BC 40 or Casi-Rusco 40 P10001, Verkada40, BC40 or Casi40 the other three of the four
46 HID H800002 H800002
48 HID Corporate 1000, 48 bit C1k48s (C-1000)
50 AWID 50 AWID50
56 Avigilon 56 Avig56 IR56
64 HID H10309, named and stored with its bits. The facility code and card number are not decoded H10309
Any other length Stored with every bit, so a format the board cannot name is still recorded Unknown

The reader's own Decode view lists a read as every format of its bit length, 44 formats in all, each with its facility code and card number. Choose one to view the read as that format, with its parity. ATLAS gives a captured card a dropdown of its readings.

Clock and Data (Paxton Net2)
Bits What it is Logged as
75 A Paxton Net2 token, fob or card Net2/EM, with the token's number and the token's EM hex for cloning. No facility code
55 or 56 One key pressed on a Paxton keypad PIN
Reader Mode
Reader Mode What it means When to pick it
Auto, the factory setting The board reads as Wiegand until it sees clock and data, then changes itself. A Paxton reader is recognized on its first card, and that card is read Leave it here
Wiegand (HID) Fixed to Wiegand The reader is Wiegand and you want the mode pinned
Clock and Data (Paxton) Fixed to clock and data The reader is a Paxton and you want the mode pinned

When what the reader sends does not match the mode, or the two data wires are crossed, the board says so on its Dashboard page and ATLAS raises a Reader Wiring notification.

What the Board Does With Every Read

Each read is stored on the board with its bit length, format name, facility code, card number, hex and raw bits. The reader has no clock of its own. It takes the time from its page or from ATLAS when one connects, and the reads from that power cycle then carry a date and time.

Its Own Web Pages, Over WiFi

The board joins a WiFi network you give it, which in the field is your phone's hotspot, and serves its pages on that network. It captures the whole time, on a network or not.

  • With no saved network, it offers its own setup network, doppelganger_XXXX, where XXXX is the last four hex digits of its MAC. The password is UndertheRadar. The setup page opens when you join, or at http://192.168.4.1/setup.
  • The setup network reaches the setup page and nothing else. No captured read is served on it. The blue STAT light is on for as long as it is offered, and it closes after 3 minutes with nobody on it, or 10 minutes with a device on it.
  • A board with a saved network looks for it for a minute from the factory before it offers setup. That wait is set in ATLAS, under SETUP NETWORK, Offered After.
  • On its network, open http://rfid.local or the address the network gave it. No app and no login. Cards lists every stored read, a read opens with its hex, its bits and every other format of the same length, the download control saves the reads as a file, and Reset, ERASE STORED CARD DATA clears them.
  • On a network with a route to the internet, Notifications under Settings emails each read as it is taken.
The Two Cards

A Core acts on two cards instead of storing them. Neither is ever logged as a capture. A Core has no stealth card.

Card From the factory What presenting it does
Reset card 35 bit, facility code 111, card number 4444, or 0000004444 on a Paxton reader, where the cards are entered as ten hex characters A full factory reset. Every setting and the saved WiFi network go, every phone paired from ATLAS is removed, Reader Mode returns to Auto, and the board comes back offering its setup network. The captured cards are kept
Pairing card None until you choose one in ATLAS With a phone waiting to pair from ATLAS, it pairs that phone. With none waiting, a reader on Bluetooth forgets every paired phone and restarts on WiFi, keeping its cards and settings, and a reader on WiFi does nothing

The reset card is set as a bit length of 26, 35, 37 or 48 with a facility code and a card number. The pairing card is 26 bit H10301, 35 bit Corporate 1000, 37 bit H10304 or 48 bit Corporate 1000, and cannot be the same card as the reset card. Both have to be cards your reader can read. The factory reset card is published, so set it on the reader's page under Settings, Reset Card Settings, or in ATLAS, to a value the site will never present.

Doppelgänger ATLAS, Over WiFi or Bluetooth

ATLAS connects to the reader over Bluetooth or WiFi. It shows each read on your phone as it is taken with a Card Captured notification, files it under a project with the reader that took it and where you were standing, and holds the reader's settings and firmware updates.

ATLAS over WiFi ATLAS over Bluetooth
How the phone connects The reader is on the phone's hotspot, and the app finds it there The app links to the reader by itself when it is in range
Setting it up Put the reader on the hotspot, as above Once, with the reader on WiFi, using a pairing card you choose and carry
Reads already on the reader IMPORT copies them into the card database under a project Delivered by themselves when the phone links
The reader's own page WEB APP opens it inside the app Not served
Cards in transit Plain HTTP on the hotspot Encrypted and authenticated, message by message

An import copies. The reader still holds every read until you run WIPE ALL CARDS under CONFIGURE, or erase it from its own page.

RESET on the board, pressed twice inside five seconds, forgets the saved WiFi network and restarts the board. Captured cards are kept.

Two Spare Outputs

IO35 and IO36 are outputs the firmware pulses each time a card is read, with +5V, +3V3 and GND pads beside them. Wire a haptic buzzer for a silent confirmation that a badge was captured, or a relay to release a maglock as a mock door controller. Both are off from the factory and set under GPIO CONFIGURATION: enable each pin, choose whether it idles high, and set a pulse of 100 to 10000 ms on the board's page or 1 to 60000 ms in ATLAS, 1000 ms from the factory.

Power

12 VDC in, on the 5.5 by 2.1 mm barrel jack (marked 7.5 - 12VDC) or the two position ALT PWR IN terminal. Whatever goes in comes out to the reader at PWR (12V).

Never more than 12 VDC, and one 12 V source at a time: the barrel jack or ALT PWR IN, never both. Overvoltage can overheat the board or start a fire, and the same voltage is passed straight through to your reader. Check polarity on the screw terminal before power goes on. A board damaged by wiring or voltage misuse is not replaced. Power it on, off and on again at every start.

Specifications

Processor module ESP32-S3-MINI-1-N8, 8 MB flash
WiFi 802.11 b/g/n at 2.4 GHz
Reader data Two lines, each behind a voltage divider that accepts a 5 V signal
Supply in 12 VDC. The board is marked 7.5 - 12VDC
Supply out The input passed through at PWR (12V), plus +5V and +3V3
Spare outputs GPIO 35 and GPIO 36
USB USB-C, ESD protected, for firmware updates and the serial console
Lights PWR, red. STAT, blue
Buttons BOOT and RESET

Plug-and-Play Installation

Wire your RFID reader, your power supply, and a haptic buzzer or relay on IO35 or IO36 if you want one. Four wires go to the reader, in 22 AWG solid core in red, black, green and white. The board comes with a 3D printed base and adhesive strip for easy mounting and deployment. If you are not confident wiring a board to a reader, buy an assembled PPE interpreter.

Included in the Box

  • Doppelgänger RFID Development Board
  • 3D printed mounting base
  • Adhesive mounting strip

You supply the reader, a 12 VDC supply, and wire.

Product Documentation

Legal Disclaimer

This device is intended for use by professional physical security practitioners during authorized access control assessments. Unauthorized use is strictly prohibited. Practical Physical Exploitation (PPE) and Mayweather Group LLC assume no liability for misuse or deployment outside the scope of authorized engagements.

Intended use

PPE products are professional tools for security practitioners working under contract or in the course of their employment, with the authorization of the site's owner. They are used to perform security audits, to help integrators confirm that an installation is secure, and to audit the work integrators and installers have done, so that flaws are found and remediated before someone with bad intentions finds them. They are not research devices, they are not sold as research devices, and they are not for any illegal or unauthorized purpose.

The manufacturers whose readers and credentials these products are used with make very secure products when those products are implemented properly. An audit shows where an installation falls short of that, so it can be corrected.